QUINT-PS 1AC /24DC/20/CO

QUINT-PS 1AC /24DC/20/CO

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    PHOENIX CONTACT - QUINT-PS 1AC /24DC/20/CO - AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 24 VD...

  • 数据手册
  • 价格&库存
QUINT-PS 1AC /24DC/20/CO 数据手册
Extract from the online catalog     QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2320898   DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective fuse breaking) technology can also be used to trigger standard circuit breakers quickly and reliably.   Product notes WEEE/RoHS-compliant since: 16/07/2009 Commercial data EAN 4 046356 520003 Pack 1 Customs tariff 85044082 Country of Origin TH Catalog page information Page 625 (IF-2011) Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http:// www.download.phoenixcontact.com. The General Terms and Conditions of Use apply to Internet downloads. Product description QUINT POWER power supply units – Maximum system availability with SFB technology Compact power supply units of the new QUINT POWER generation maximize the availability of your system. With the SFB technology (Selective Fuse Breaking Technology), six times the nominal current for 12 ms, even the standard power circuit-breakers can now also be triggered reliably and quickly. Faulty current paths are switched off selectively, the fault is located and important system parts continue to operate. Comprehensive diagnostics are provided through constant monitoring of output voltage and current. This preventive function monitoring visualizes critical operating modes and reports them to the control unit before an error can occur. PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 1 / 7 20-Jan-2012 QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2320898 Technical data Input data Nominal input voltage 100 V AC ... 240 V AC AC input voltage range 85 V AC ... 264 V AC DC input voltage range 90 V DC ... 350 V DC (UL 508: ≤ 250 V DC) Short-term input voltage 300 V AC AC frequency range 45 Hz ... 65 Hz DC frequency range 0 Hz Current consumption Approx. 5.1 A (120 V AC) Approx. 2.3 A (230 V AC) Inrush surge current < 20 A (typical) Power failure bypass > 20 ms (120 V AC) > 20 ms (230 V AC) Input fuse 12 A (slow-blow, internal) Permissible backup fuse B10 B16 Additional text AC: 1 x circuit breaker - recommended fuse Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC ±1% Setting range of the output voltage 18 V DC ... 29.5 V DC (> 24 V constant capacity) Output current 20 A (-25°C ... 60°C, UOUT = 24 V DC) 26 A (with POWER BOOST, -25°C ... 40°C permanently, UOUT = 24 V DC) 120 A (SFB technology, 12 ms) 26 A (UIn ≥ 100 V AC) Magnetic fuse tripping B16 C6 Derating 60 °C ... 70 °C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series Yes Control deviation < 1 % (change in load, static 10% ... 90%) < 2 % (change in load, dynamic 10% ... 90%) < 0.1 % (change in input voltage ±10%) PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 2 / 7 20-Jan-2012 QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2320898 Residual ripple < 30 mVPP (with nominal values) Maximum power dissipation idling 8W Power loss nominal load max. 40 W General data Width 90 mm Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm 93 mm Net weight 1.7 kg Efficiency > 93 % (for 230 V AC and nominal values) Insulation voltage input/output 4 kV AC (type test) 2 kV AC (routine test) Degree of protection IP20 Protection class I MTBF (IEC 61709, SN 29500) > 500000 h (According to IEC 61709) Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating) Ambient temperature (storage/transport) -40 °C ... 85 °C Max. permissible relative humidity (operation) 100 % (at 25 °C, no condensation) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Can be aligned: 5 mm horizontally, 15 mm next to active components, 5 cm vertically Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Standard – Electrical equipment of machines EN 60204 Standard - Safety of transformers IEC 61558-2-17 Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) Shipbuilding approval Germanischer Lloyd (EMC 1, only with upstream filter), ABS, LR, RINA, NK, DNV, BV Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204 (PELV) Standard - Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Standard – Protection against electric shock PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk DIN 57100-410 Page 3 / 7 20-Jan-2012 QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2320898 Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment DIN VDE 0106-101 Standard – Limitation of mains harmonic currents EN 61000-3-2 Standard – Equipment safety BG (design tested) Standard - Approval for medical use IEC 60601 Approval - requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706 Compliance Certificate Certificate CB Scheme UL approvals UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950 Surge voltage category III DeviceNet approval DeviceNet™ Power Supply Conformance Tested Connection data, input Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 6 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 4 mm² Conductor cross section AWG/kcmil min. 18 Conductor cross section AWG/kcmil max 10 Stripping length 7 mm Screw thread M4 Connection data, output Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 6 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 4 mm² Conductor cross section AWG/kcmil min. 12 Conductor cross section AWG/kcmil max 10 Stripping length 7 mm Signaling Output name DC OK active Output description UOUT > 0.9 x UN: High signal PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 4 / 7 20-Jan-2012 QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2320898 Maximum inrush current min. 20 mA (short-circuit resistant) Continuous load current ≤ 20 mA Status display UOUT > 0.9 x UN: "DC OK" LED green Note on status display UOUT < 0.9 x UN: Flashing "DC OK" LED IOUT < IN: LED ON Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 6 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 4 mm² Conductor cross section AWG/kcmil min. 18 Conductor cross section AWG/kcmil max 10 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Screw thread M4 Output name DC OK floating Output description Relay contact, UOUT > 0.9 x UN: Contact closed Maximum switching voltage ≤ 30 V AC/DC Maximum inrush current ≤1A Continuous load current ≤1A Status display UOUT > 0.9 x UN: "DC OK" LED green Note on status display UOUT < 0.9 x UN: Flashing "DC OK" LED Output name POWER BOOST, active Output description IOUT < IN: High signal Output voltage + 24 V DC Maximum inrush current min. 20 mA (short-circuit resistant) Continuous load current ≤ 20 mA Status display IOUT > IN: LED "BOOST" yellow Certificates Certification PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk CB, CSA, CUL, GL, GOST, UL, UL Listed Page 5 / 7 20-Jan-2012 QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2320898 Accessories Item Designation Description 2319919 ME-MAX-NEF/QUINT20A Filter for adherence to the EMC category EMC1 in shipbuilding for the QUINT-PS/1AC/24DC/20 power supply 2320076 QUINT-PS/FAN/4 The fan for QUINT-PS/1AC and .../3AC power supply units can be mounted without the need for tools or other accessories. By using the fan, optimum cooling is ensured at high ambient temperatures or if the mounting position is rotated. 2938235 UWA 182/52 Universal wall adapter General Drawings Block diagram PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 6 / 7 20-Jan-2012 QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2320898 Address PHOENIX CONTACT Ltd Halesfield 13 Telford / Shropshire / TF7 4PG,England Phone 01952 681 700 Fax 01952 681 799 http://www.phoenixcontact.co.uk Phoenix Contact Ltd. Technical modifications reserved; PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 7 / 7 20-Jan-2012
QUINT-PS 1AC /24DC/20/CO 价格&库存

很抱歉,暂时无法提供与“QUINT-PS 1AC /24DC/20/CO”相匹配的价格&库存,您可以联系我们找货

免费人工找货